Title: bizhub 165-185 Brochure.cdr Author: OD2 Created Date: 4/12/2016 1:04:01 PM. Scanning a 2-sided original (Simplex/Duplex) Using the ADF, you can automatically scan the front and back faces of an original.Also, you can scan only one side of the first page, then scan both sides of the remaining pages. Multifunctional Bizhub 185 Printer konica Minolta bizhub 306, 30 page per minute copy, network print, network scann, photocopier, multifunction printer, copier, xerox machine from macgray solutions private limited gujarat india ahmedabad, other speed konica minolta 206, 20 page per minutes, konica minolta bizhub 226,22 page per minutes konica minolta bizhub 266, 26, page per.
Konica 195
Code: C0211
Description: Bypass tray lift-up failure • When a print cycle is completed, a jam is fixed, or the power switch is turned ON, if the bypass lift sensor (PS4) does not change from the unblocked to blocked condition after the lapse of a given period of time after the bypass pick-up solenoid (SD1) is turned ON, the machine retries the depressing motion. This trouble code is displayed if the PS4 is not blocked after the retry. • While the bypass lift sensor (PS4) is blocked, if the PS4 is not unblocked after the lapse of a given period of time after the bypass pick-up solenoid (SD1) is turned ON, the machine retries the lifting motion. • This trouble code is displayed if the PS4 is not unblocked after the retry.
Causes: Bypass lift sensor (PS4) Bypass pick-up solenoid (SD1) Main motor (M1) Printer control board (PRCB)
Remedy: 1 Check the connector between M1-PRCB CN6 for proper connection and correct as necessary. 2 Check M1 for correct drive coupling and correct as necessary. 3 Check the connector between PS4-relay CN6-PRCB CN8 for proper connection and correct as necessary. 4 Check the connector between SD1-relay CN4-relay CN6-PRCB CN8 for proper connection and correct as necessary. 5 PS4 I/O check, sensor check. PRCB CN8-8 (ON) 11-E 6 M1 operation check. PRCB CN6-7 (LOCK) 9-D 7 SD1 operation check. PRCB CN8-12 (REM) 11-E 8 Change PRCB.
Code: C2351
Description: Suction fan motor malfunction • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Suction fan motor (FM5) Printer control board (PRCB)
Remedy: 1 Check the connector between FM5-relay CN13-PRCB CN14 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM5 operation check. PRCB CN14-2(REM) 3-E 4 Change PRCB.
Code: C2557
Description: Abnormally low T/C ratio • The T/C ratios detected by the TCR sensor board (TCRSB) are below the threshold for the detection of abnormally low T/C ratio for three successive times. However, if a toner empty condition is detected, this abnormality is not detected.
Causes: TCR sensor board (TCRSB) Printer control board (PRCB)
Remedy: 1 Check to see if developer is available. 2 Check the connector between TCRSB-relay CN14-PRCB CN10 for proper connection and correct as necessary. 3 Change TCRSB. 4 Change PRCB.
Code: C2558
Description: Abnormally high T/C ratio • The T/C ratios detected by the TCR sensor board (TCRSB) are above the threshold for the detection of abnormally high T/C ratio for three successive times. • The connector between TCRSB to PRCC is disconnected.
Causes: TCR sensor board (TCRSB) Printer control board (PRCB)
Remedy: 1 Check to see if developer is available. 2 Check the connector between TCRSB-relay CN14-PRCB CN10 for proper connection and correct as necessary. 3 Change TCRSB. 4 Change PRCB.
Code: C255C
Description: TCR sensor adjustment failure . When [SERVICE MODE] - [FUNCTION] - [TCR AUTO ADJUST] is performed, the difference between the TCR sensor output voltage determined by TCR AUTO ADJUST and the standard voltage is greater than the given value
Causes: TCR sensor board (TCRSB) Printer control board (PRCB)
Remedy: 1 Check to see if developer is available. 2 Check the connector between TCRSB-relay CN14-PRCB CN10 for proper connection and correct as necessary. 3 Change TCRSB. 4 Change PRCB.
Konica 185e Price
Code: C2702
Description: Abnormal image transfer voltage • The image transfer voltage remains more than 100 V continuously for a given period of time while the drum remains stationary.
Causes: Transfer roller unit High voltage unit (HV1) Printer control board (PRCB)
Remedy: 1 Check the transfer roller unit for installation. 2 Change HV1. 3 Change PRCB.